Proxmox VE 3.2 on 3 nodes + Ceph - rbd error

$
0
0
Hi,
I'm trying to install Proxmox on 3 nodes and setup Ceph. Proxmox part works very well.
Problem begins while setting up Ceph. I followed this howto: http://www.jamescoyle.net/how-to/121...age-on-proxmox. Each step is done without any problem.
But when instalation is finished and I want to create VM I'm getting this error:

rbd error: rbd: couldn't connect to the cluster! (500)



and VM is not created. Can anyone tell me what is wrong? I spent many hours trying to figure it out but I'm loosing my confidence :(
Thanks a lot in advance.

ceph kvm file system type. ext4 or xfs?

$
0
0
Hello

from what I read at http://forum.proxmox.com/threads/185...ce-and-latency , It seems that for within a kvm it is better to use ext4 .

all our ceph kvm's use xfs for data storage disks... the ceph node kvm's are not as fast for some current disk io. ceph nodes show greater i/o delays at pve> summary ..


So the question is - for now does it make sense to use ext4 as default for kvm disks hosted on ceph?

Help Setting up Shared Block Device using Fibre-Channel

$
0
0
Hello,
After spending hours researching this, I finally give up. I have a NAS that directly connects to 4 Proxmox nodes using fibre-channel, and is sharing the same block device to all 4 nodes. Each Proxmox node sees the block device as /dev/sdc, but what I am trying to do is get "clustered" journaling working so I can use the storage for High Availability migrations.

I have tried OCFS2 as the file format, but the PVE Kernel has it disabled.
I tried Ceph, but it does not seem to do what I need (unless I am missing something?)
GlusterFS is the same story as Ceph, it seems to be able to "replicate", but doing that to the same "block" device would cause nothing but journal issues.
The only thing I was able to get to work at all was GFS2, but I was not very impressed with the speeds.

So, any hints/tips/tricks on getting a shared block device to work across 4 nodes for High Availability?

Also, because it seems to always be asked, here is my pveversion info:
Code:

root@C6100-1-N1:/boot# pveversion -vproxmox-ve-2.6.32: 3.2-126 (running kernel: 3.10.0-2-pve)
pve-manager: 3.2-4 (running version: 3.2-4/e24a91c1)
pve-kernel-2.6.32-27-pve: 2.6.32-121
pve-kernel-2.6.32-28-pve: 2.6.32-124
pve-kernel-3.10.0-2-pve: 3.10.0-10
pve-kernel-2.6.32-29-pve: 2.6.32-126
pve-kernel-2.6.32-26-pve: 2.6.32-114
lvm2: 2.02.98-pve4
clvm: 2.02.98-pve4
corosync-pve: 1.4.5-1
openais-pve: 1.1.4-3
libqb0: 0.11.1-2
redhat-cluster-pve: 3.2.0-2
resource-agents-pve: 3.9.2-4
fence-agents-pve: 4.0.5-1
pve-cluster: 3.0-12
qemu-server: 3.1-16
pve-firmware: 1.1-3
libpve-common-perl: 3.0-18
libpve-access-control: 3.0-11
libpve-storage-perl: 3.0-19
pve-libspice-server1: 0.12.4-3
vncterm: 1.1-6
vzctl: 4.0-1pve5
vzprocps: 2.0.11-2
vzquota: 3.1-2
pve-qemu-kvm: 1.7-8
ksm-control-daemon: 1.1-1
glusterfs-client: 3.4.2-1

Thanks

Migrate VM from proxmox 1.9 to 3.2

$
0
0
Hello,

We have an old Proxmox 1.9 that hosts important VMs.
I've installed a new server with Promox 3.2 and I would like to know if there is a way to migrate VMs from 1.9 to 3.2? (if necessary via a 2.x).

Thank you for your advices.
Guillaume.

Java error authentication failed between PVE nodes

$
0
0
Hi to all

I have a PVE cluster, with PVE nodes 2.3, 3.1 and 3.2 versions
My Windows workstation have Java Version 7 Update 60

I have a problem with the Java VM consoles, ie that if i am connected to a PVE node that have 3.2 version and want the Java console of some VM that is in the same host, work very well, but if i want the Java console of a VM that is in other node that have PVE 3.2 version, don't work and see this message "Error: Authentication failed". And finally if i want the Java console of a VM that is in a old node that have PVE 2.3 version, very well.

My questions are what is the problem with PVE 3.2 version and how fix it?

Installing Proxmox 3.2 on a Mac Mini

$
0
0
Hey All, I'm not sure if this kind of thing is welcome here or not, but I recently had to reinstall Proxmox on one of the nodes in my lab, and it proved to be quite the challenge. I wrote a blog post so I can reference it in the future if needed, and I though I would share it: http://unixschool.org/installing-pro...on-a-mac-mini/

unable to parse worker upid When I try to do vzrestore

$
0
0
Hi. I did a vzdump from a 2.1 proxmox node, and then copied the dump to a proxmox 2.2 node. When I tried to do the vzrestore from the 2.2 node I got this error:unable to parse worker upid 'UPID:mymachine:00094940:1221122CF:539CE448:vzrest ore:107:root@pam:'Is possible that error comes for different proxmox versions between nodes?. If yes, how can upgrade from 2.1 to 2.2 safely to lauch again the vzdump/vzrestore?thanks in advance :)

ksoftirqd/0 high cpu usage

$
0
0
Hi,

we've got a problem with one of our proxmox nodes. ksoftirqd/0 eats here sometimes 100% CPU on Core 0 (system has dual xeon E5-2620v2, 256 GB RAM, RAID6) and network is then slow /w packet loss.

We already bootet with kernel options nohz=off and pcie_aspm=off but it did not help. Overall load on the system is ~2.0 - 3.0, so this should not be the problem here.

The machine runs latest PVE with latest kernel:

Quote:

proxmox-ve-2.6.32: 3.2-126 (running kernel: 2.6.32-29-pve)pve-manager: 3.2-4 (running version: 3.2-4/e24a91c1)
pve-kernel-2.6.32-27-pve: 2.6.32-121
pve-kernel-2.6.32-29-pve: 2.6.32-126
pve-kernel-2.6.32-26-pve: 2.6.32-114
pve-kernel-2.6.32-23-pve: 2.6.32-109
lvm2: 2.02.98-pve4
clvm: 2.02.98-pve4
corosync-pve: 1.4.5-1
openais-pve: 1.1.4-3
libqb0: 0.11.1-2
redhat-cluster-pve: 3.2.0-2
resource-agents-pve: 3.9.2-4
fence-agents-pve: 4.0.5-1
pve-cluster: 3.0-12
qemu-server: 3.1-16
pve-firmware: 1.1-3
libpve-common-perl: 3.0-18
libpve-access-control: 3.0-11
libpve-storage-perl: 3.0-19
pve-libspice-server1: 0.12.4-3
vncterm: 1.1-6
vzctl: 4.0-1pve5
vzprocps: 2.0.11-2
vzquota: 3.1-2
pve-qemu-kvm: 1.7-8
ksm-control-daemon: 1.1-1
glusterfs-client: 3.4.2-1
Is there a problem with the interrups or something? Help or any hint would be appreciated - thanks!

ceph disk detail from cli

$
0
0
Hello,
is there a ceph cli command which will list disk detail like serial number and which journal is used?

It is not possible to copy and paster [ for me ] the serial number from web gui.. I'm trying to put 20 serial numbers to a table so i can cross reference drive position in chassis to osd number etc.

network switch type for network bonding

$
0
0
for pve cluster I want to set up a network bond using four or more Gigabit Intel server nics at each node.

My question is - what is the best type of switch, manged or unmanaged?

Permission denied From Clean start?!!!!

$
0
0
so brand new clean install and i am trying to change things ip address hostname, and then make a cluster but i keep getting permission denied when i try to edit something either local or remote through putty!

can someone please help as this is real annoying
i have searched the forum and only found similar issues when a cluster exist but this is a clean out the box install

login as: root
root@192.168.10.26's password:
Linux proxmox 2.6.32-29-pve #1 SMP Thu Apr 24 10:03:02 CEST 2014 x86_64

The programs included with the Debian GNU/Linux system are free software;
the exact distribution terms for each program are described in the
individual files in /usr/share/doc/*/copyright.

Debian GNU/Linux comes with ABSOLUTELY NO WARRANTY, to the extent
permitted by applicable law.
Last login: Sun Jun 15 19:38:55 2014 from 192.168.10.9
root@proxmox:~# /etc/hostname
-bash: /etc/hostname: Permission denied
root@proxmox:~#

root@proxmox:~# /etc/network/interfaces
-bash: /etc/network/interfaces: Permission denied
root@proxmox:~#



thanks mattman110

VZDump hangs

$
0
0
Hi,
on a new N54L i have instaled v. 3.2-54885216-5 from cd and then updated to the latest version (12/06/2014 or 13/06/2014)
Mounted a dir (cifs) pointing a server that contains backup data.
Restored an old backup (KVM VM). Trying to make a new backup of the restored vm the backup hunged. :(

Wiped out and installed v.3.0-0428106c-13 without updating it.
Restored the same VM. The backup worked fine serveral time and no problems. :D

I have the same problem on a production server with 3.1.21 93bf03d4; the problem appeared after an update, before it the backups where performed right.

I noted this: in the v3.0 the data transfer to the server hosting backup files starts immediately, with v3.1 and v3.2 data transfer don't start, the window initially shows the progress with new report lines then stops and remain freezed, LAN is inactive.

There is a way to solve this problem?

Thank you

Web interface Authentication failed. Please try again.

$
0
0
Hi,

I have a 2.2 installation running. I had to restart the server. I was able to log in to the web interface once. Now, three days later it always tells me Authenticaiton failed. Please try again.
I am using PAM authentication, same password, same login, nothing changed, only restarted. I cannot see why it is not working, but I have no clue what services need to be running.

Please, can anyone help?
Thanks

Proxmox not start after shutdown and LVM dir fail

$
0
0
Hi.If a machine with LVM directory for use with machines (not LVM disk)vm XXX -- unable to parse value of template --uknown setting templatevm XXX -- unable to parse value of template --uknown setting templatetemplate /var/lib/template its mount over LVM logical volumen that fail and reboot.System Up, after 5 minuts but:Only 2 KVM (work)Imposisble apt-get updateImpossible to access :8006 or webmin :10000Desesperate...also /etc/network/if-up.d/ntpdate: line 45: kill

Optimize Dell PowerEdge 2950 Disk Performance ?

$
0
0
I got a Dell 2950 with a PERC 5/i Integrated Raid Controller with 4x300GB SAS HDD and like to get a better Performance.

Some Infos:

Code:

pveperf

CPU BOGOMIPS:      15960.32
REGEX/SECOND:      762587
HD SIZE:          19.69 GB (/dev/mapper/pve-root)
BUFFERED READS:    232.04 MB/sec
AVERAGE SEEK TIME: 4.05 ms
FSYNCS/SECOND:    53.75
DNS EXT:          108.81 ms
DNS INT:          48.40 ms


pveperf /var/lib/vz

CPU BOGOMIPS:      15960.32
REGEX/SECOND:      780605
HD SIZE:          757.06 GB (/dev/mapper/pve-data)
BUFFERED READS:    245.78 MB/sec
AVERAGE SEEK TIME: 6.81 ms
FSYNCS/SECOND:    45.84
DNS EXT:          101.97 ms
DNS INT:          46.68 ms



Code:

megacli -AdpAllInfo -aAll

Adapter #0

==============================================================================
                    Versions
                ================
Product Name    : PERC 5/i Integrated
Serial No      : XXXXX
FW Package Build: 5.0.2-0003

                   
                Image Versions in Flash:
                ================
Boot Block Version : R.2.3.2
BIOS Version      : MT23
MPT Version        : MPTFW-00.06.71.00-IT
FW Version        : 1.00.02-0157
WebBIOS Version    : 1.01-021
Ctrl-R Version    : 1.02-007


                HW Configuration
                ================
SAS Address      : XXXXXXX
BBU              : Present
Alarm            : Present
NVRAM            : Present
Serial Debugger  : Present
Memory          : Present
Flash            : Present
Memory Size      : 256MB
TPM              : Absent
On board Expander: Absent
Upgrade Key      : Absent
Temperature sensor for ROC    : Absent
Temperature sensor for controller    : Absent


                Settings
                ================
Current Time                    : 14:50:11 6/16, 2014
Predictive Fail Poll Interval    : 300sec
Interrupt Throttle Active Count  : 16
Interrupt Throttle Completion    : 50us
Rebuild Rate                    : 30%
PR Rate                          : 30%
BGI Rate                        : 30%
Check Consistency Rate          : 30%
Reconstruction Rate              : 30%
Cache Flush Interval            : 4s
Max Drives to Spinup at One Time : 2
Delay Among Spinup Groups        : 12s
Physical Drive Coercion Mode    : 128MB
Cluster Mode                    : Disabled
Alarm                            : Disabled
Auto Rebuild                    : Enabled
Battery Warning                  : Enabled
Ecc Bucket Size                  : 15
Ecc Bucket Leak Rate            : 1440 Minutes
Restore HotSpare on Insertion    : Disabled
Expose Enclosure Devices        : Disabled
Maintain PD Fail History        : Disabled
Host Request Reordering          : Enabled
Auto Detect BackPlane Enabled    : SGPIO/i2c SEP
Load Balance Mode                : Auto
Use FDE Only                    : No
Security Key Assigned            : No
Security Key Failed              : No
Security Key Not Backedup        : No
Default LD PowerSave Policy      : Controller Defined
Maximum number of direct attached drives to spin up in 1 min : 0
Auto Enhanced Import            : No
Any Offline VD Cache Preserved  : No
Allow Boot with Preserved Cache  : No
Disable Online Controller Reset  : No
PFK in NVRAM                    : No
Use disk activity for locate    : No
POST delay                      : 90 seconds
BIOS Error Handling              : Stop On Errors
Current Boot Mode                :Normal
                Capabilities
                ================
RAID Level Supported            : RAID0, RAID1, RAID5, RAID00, RAID10, RAID50, SRL 3 supported
Supported Drives                : SAS, SATA

Allowed Mixing:

Mix in Enclosure Allowed

                Status
                ================
ECC Bucket Count                : 0

                Limitations
                ================
Max Arms Per VD          : 32
Max Spans Per VD        : 8
Max Arrays              : 128
Max Number of VDs        : 64
Max Parallel Commands    : 1008
Max SGE Count            : 80
Max Data Transfer Size  : 8192 sectors
Max Strips PerIO        : 84
Max LD per array        : 0
Min Strip Size          : 8 KB
Max Strip Size          : 128 KB
Max Configurable CacheCade Size: 0 GB
Current Size of CacheCade      : 0 GB
Current Size of FW Cache      : 0 MB

                Supported Adapter Operations
                ================
Rebuild Rate                    : Yes
CC Rate                        : Yes
BGI Rate                        : Yes
Reconstruct Rate                : Yes
Patrol Read Rate                : Yes
Alarm Control                  : Yes
Cluster Support                : No
BBU                            : Yes
Spanning                        : Yes
Dedicated Hot Spare            : Yes
Revertible Hot Spares          : No
Foreign Config Import          : Yes
Self Diagnostic                : Yes
Allow Mixed Redundancy on Array : No
Global Hot Spares              : Yes
Deny SCSI Passthrough          : No
Deny SMP Passthrough            : No
Deny STP Passthrough            : No
Support Security                : No
Snapshot Enabled                : No
Support the OCE without adding drives : No
Support PFK                    : No
Support PI                      : No
Support Boot Time PFK Change    : No
Disable Online PFK Change      : No
Support Shield State            : No
Block SSD Write Disk Cache Change: No

                Supported VD Operations
                ================
Read Policy          : Yes
Write Policy        : Yes
IO Policy            : Yes
Access Policy        : Yes
Disk Cache Policy    : Yes
Reconstruction      : Yes
Deny Locate          : No
Deny CC              : No
Allow Ctrl Encryption: No
Enable LDBBM        : No
Support Breakmirror  : No
Power Savings        : No

                Supported PD Operations
                ================
Force Online                            : Yes
Force Offline                          : Yes
Force Rebuild                          : Yes
Deny Force Failed                      : No
Deny Force Good/Bad                    : No
Deny Missing Replace                    : No
Deny Clear                              : No
Deny Locate                            : No
Support Temperature                    : No
NCQ                                    : No
Disable Copyback                        : No
Enable JBOD                            : No
Enable Copyback on SMART                : No
Enable Copyback to SSD on SMART Error  : No
Enable SSD Patrol Read                  : No
PR Correct Unconfigured Areas          : No
                Error Counters
                ================
Memory Correctable Errors  : 0
Memory Uncorrectable Errors : 0

                Cluster Information
                ================
Cluster Permitted    : No
Cluster Active        : No

                Default Settings
                ================
Phy Polarity                    : 0
Phy PolaritySplit                : 0
Background Rate                  : 30
Strip Size                      : 64kB
Flush Time                      : 4 seconds
Write Policy                    : WB
Read Policy                      : None
Cache When BBU Bad              : Disabled
Cached IO                        : No
SMART Mode                      : Mode 6
Alarm Disable                    : No
Coercion Mode                    : 128MB
ZCR Config                      : IDSEL
Dirty LED Shows Drive Activity  : No
BIOS Continue on Error          : 0
Spin Down Mode                  : None
Allowed Device Type              : SAS/SATA Mix
Allow Mix in Enclosure          : Yes
Allow HDD SAS/SATA Mix in VD    : No
Allow SSD SAS/SATA Mix in VD    : No
Allow HDD/SSD Mix in VD          : No
Allow SATA in Cluster            : No
Max Chained Enclosures          : 1
Disable Ctrl-R                  : No
Enable Web BIOS                  : No
Direct PD Mapping                : No
BIOS Enumerate VDs              : No
Restore Hot Spare on Insertion  : No
Expose Enclosure Devices        : No
Maintain PD Fail History        : No
Disable Puncturing              : No
Zero Based Enclosure Enumeration : No
PreBoot CLI Enabled              : Yes
LED Show Drive Activity          : No
Cluster Disable                  : Yes
SAS Disable                      : No
Auto Detect BackPlane Enable    : SGPIO/i2c SEP
Use FDE Only                    : No
Enable Led Header                : No
Delay during POST                : 0
EnableCrashDump                  : No
Disable Online Controller Reset  : No
EnableLDBBM                      : No
Un-Certified Hard Disk Drives    : Block
Treat Single span R1E as R10    : No
Max LD per array                : 16
Power Saving option              : All power saving options are enabled
Default spin down time in minutes: 0
Enable JBOD                      : No
Time taken to detect CME        : 60s

Exit Code: 0x00




Is the Battery OK ?


Code:

megacli -AdpBbuCmd -GetBbuStatus -a0 | grep -e '^isSOHGood' -e '^Charger Status' -e '^Remaining Capacity'

Charger Status: Complete
Remaining Capacity: 0 mAh
isSOHGood: Yes


cant provision from template.

$
0
0
I am newbie to proxmox. I had tried to install VM using ISO (kvm). It worked fine. But when i tried to create CT from system appliance, it is showing as "running", but the console is showing black screen with ` symbol. Do i missed something? I just copied the template tar.gz to the template path. What is the performance difference between vm and ct? Which is better in production and please tell me the major differences?

Error some ware

$
0
0
cant log in to web gui but can ssl and local. after update and changing my FQDN

banner displays http://81.200.64.50:8006

host

127.0.0.1 localhost.localdomain.localhost
192.168.10.26 DellPE2950-2.HHN.local

# The following lines are desirable for IPv6 capable hosts

::1 ip6-localhost ip6-loopback
fe00::0 ip6-localnet
ff00::0 ip6-mcastprefix
ff02::1 ip6-allnodes
ff02::2 ip6-allrouters
ff02::3 ip6-allhosts


interfaces


auto lo
iface lo inet loopback

auto vmbr0
iface vmbr0 inet static
address 192.168.10.26
netmask 255.255.255.0
network 192.168.10.0
bradcast 192.168.10.255
gateway 192.168.10.1
bridge_ports eth0
bridge_stp off
bridge_fd 0


netstat -apa

tcp 0 0 *:8006 *:* LISTEN 2483/pveproxy

I can't reach gateway from CT

$
0
0
I've done a fresh installation of latest version of Proxmox on my public server and it set vmbr0 to my Public IP 87.x.x.30, netmask 255.255.255.0 and gateway 87.x.x.1 while eth0 and eth1 aren't set. After this I created a brend new CT using official ubuntu 12.04 openvz template and setting with venet on private ip 192.168.1.51. So I tried to ping both gateway 87.x.x.1 and 8.8.8.8 without result.

Where am I wrong?

Enhance API?

$
0
0
I need to remotely do a few tasks on the proxmox servers that the current api doesnt provide. Is there a way to enhance the api in an upgrade safe fashion? If not, is there a way to expose a script to the web server that proxmox uses?

Proxmox not releasing memory

$
0
0
Hi, I have a server with 32GB. I have a VM to which I'd allocated 10GB RAM. In total the server was using 23GB memory. I destroyed this machine as it was no longer needed and attempted to create another VM with 10GB memory. It fails to boot with the error, "Cannot set up guest memory 'pc.ram': Cannot allocate memory". It seems the memory used by the old VM was not released, and the server is still using just over 23GB RAM. How do I free up the memory? I have VMs allocated 2GB + 1GB + 1GB + 8GB + 1GB = 13GB allocated, but 23GB of memory is being used. Thanks, Mike PS: Apologies for the formatting of this post, but the forum is stripping out my line breaks.