[fsyncs/second drop issue followup]: lsi raid controller bbu replaced recharging now?

$
0
0
Hi, here http://forum.proxmox.com/threads/145...-what-to-check
is the thread where I learned that my IBM serveraid BBU was to be replaced, which caused automatic Writethrough, and so fsyncs/second drop...

Now, I finally got a replaced battery, that is actually charging, but fsyncs/second are still the same, so I checked more, with:
Code:

megacli -AdpBbuCmd  -aAll

BBU status for Adapter: 0

BatteryType: iBBU
Voltage: 4063 mV
Current: 95 mA
Temperature: 28 C
Battery State    : Non Operational

BBU Firmware Status:

  Charging Status              : Charging
  Voltage                                : OK
  Temperature                            : OK
  Learn Cycle Requested                  : Yes
  Learn Cycle Active                      : No
  Learn Cycle Status                      : OK
  Learn Cycle Timeout                    : No
  I2c Errors Detected                    : No
  Battery Pack Missing                    : No
  Battery Replacement required            : No
  Remaining Capacity Low                  : No
  Periodic Learn Required                : No
  Transparent Learn                      : No
  No space to cache offload              : No
  Pack is about to fail & should be replaced : No
  Cache Offload premium feature required  : No
  Module microcode update required        : No


GasGuageStatus:
  Fully Discharged        : No
  Fully Charged          : No
  Discharging            : No
  Initialized            : Yes
  Remaining Time Alarm    : No
  Discharge Terminated    : No
  Over Temperature        : No
  Charging Terminated    : No
  Over Charged            : No
  Relative State of Charge: 29 %
  Charger System State: 49168
  Charger System Ctrl: 0
  Charging current: 512 mA
  Absolute state of charge: 29 %
  Max Error: 100 %

  Battery backup charge time : 0 hours

BBU Capacity Info for Adapter: 0

  Relative State of Charge: 29 %
  Absolute State of charge: 29 %
  Remaining Capacity: 356 mAh
  Full Charge Capacity: 1215 mAh
  Run time to empty: Battery is not being discharged.
  Average time to empty: Battery is not being discharged.
  Estimated Time to full recharge: 9 Hour, 10 Min.
  Cycle Count: 0
Max Error = 100 %
Remaining Capacity Alarm = 120 mAh
Remining Time Alarm = 10 Min

BBU Design Info for Adapter: 0

  Date of Manufacture: 03/02, 2013
  Design Capacity: 1215 mAh
  Design Voltage: 3700 mV
  Specification Info: 33
  Serial Number: 1919
  Pack Stat Configuration: 0x64a0
  Manufacture Name: LS11A1003A
  Device Name: 3150303
  Device Chemistry: LION
  Battery FRU: N/A
  Transparent Learn = 0
  App Data = 0

BBU Properties for Adapter: 0

  Auto Learn Period: 30 Days
  Next Learn time: Jan 1 200 00:00:00
  Learn Delay Interval:0 Hours
  Auto-Learn Mode: Enabled

Exit Code: 0x00

then I tried to force a BBU learn, but it fails:
Code:

  megacli -AdpBbuCmd -BbuLearn -a0

Adapter 0: BBU Learn Failed

Exit Code: 0x01

Now, anyone has experience with this? Is this normal? Will it work when charge is complete?

Or there could be other issues and how to check them?